USpace Aisle Containment

Aisle Containment

Thermodynamically advanced, cost and energy efficient, our solutions incorporate Horizontal (flat roof) and Vertical solutions spanning hot aisle or cold aisle options all of which improve cooling efficiencies specific to your data center requirements.
USpace
USpace Aisle Containment

Horizontal Aisle Containment

The design maximises cold air efficiency for optimal cooling.
USpace
USpace Aisle Containment

Vertical Aisle Containment

Vertical containment optimizes airflow by separating hot and cold aisles.

USpace Aisle Containment

Why Containment?

Many years of innovation and experience accumulated at USystems producing cutting edge data center design solutions for data centers has been channelled into developing the most effective and efficient aisle containment systems currently available.

Thermodynamically advanced, cost and energy efficient, our solutions incorporate Horizontal (flat roof) and Vertical solutions spanning hot aisle or cold aisle options all of which improve cooling efficiencies specific to your data center requirements. Each style of containment can be designed around multiple height cabinets without affecting thermal performance.
In fact the CL80 InRow is capable of handling up to 80kW total, 67kW sensible cooling per system.The combination of EC fan technology, managed air flow, water volume control and the incorporation of the ColdLogik Management System culminate in a cooling system that can grow with your heat loads.

Crucially the CL80 InRow can give a 60% energy saving over traditional data center designs.

Benefits

Up to 60% energy savings
Thermodynamically advantageous
Enhanced efficiency
Hot or cold aisle versions
Cost-effective
Low-maintenance
Custom built
Quick and easy installation
Modular
Retrofittable
Re-locatable
Expandable

USpace Aisle Containment

Learn more
about the product

Vertical Aisle Containment

Overview

About the Product

Vertical containment allows for the integration of raised floor air-conditioning into the standalone warm aisle containment – this way both rows are climatically neutral against the rest of the data center. Here at USystems we provide the very best data center air and water cooling, ensuring your data center is working at its optimum.
Thermodynamically advantageous
Enhanced efficiency
Cost-effective
Low-maintenance
Quick and easy installation
Modular
Retrofittable
Re-locatable

Vertical Aisle Containment

Ventilation

Aisle Air Containment fully encases the corridor with a rigid enclosure which maximises the efficient use of cold air being fed in through the raised floor. The corridor remains light as light transmission (LUX) from the data center is let in through the lightweight transparent ceiling panels which have a transparency of an impressive 88%.

Vertical Aisle Containment

Door Options

Electronic door - Outstanding user convenience and unique operational behaviour characterize the automatic sliding door operator. The door is magnetically driven and therefore silent in operation. Additionally the drive method allows for unparalleled levels of safety for the user.
Manual door - Outstanding user convenience and unique operational behaviour characterize the automatic sliding door operator. The door is magnetically driven and therefore silent in operation. Additionally the drive method allows for unparalleled levels of safety for the user.

Vertical Aisle Containment

Lighting

The aisle beacon is controlled by a BT10 universal interface module which takes an input from the 100v loudspeaker circuit on the building fire alarm. The BT10 and a 24v relay are mounted in a Beacon Box assembly (CC6-0100-AP). The beacon is installed in the central service panel of the aisle. The customer is responsible for arranging connection of the 110v line input from the fire alarm system.
Operation Temperature: -20˚/+50˚C
Dual voltage 12/24V (10-30Vdc)
Light Source: Chip LED
Bright, intense Xenon flash
Light Color: Natural White (3800-4200 K)
No moving parts – maintenance free
Beam Angle: 120˚ without lens
Low power consumption
Light Efficacy: 105 lm/W
3,000 hours tube life
Operation Voltage: 100-240V 50/60Hz.
Operating temperature -30°C to -55°C
Power Consumption (W): 10W/m
Beam Angle: 120˚ without lens

Horizontal Aisle Containment

Overview

About the Product

Horizontal Aisle Containment significantly reduces the load on the CRAC units leading to significant savings in operating costs. Here at USystems with our data center cooling systems we can provide drop-out ceiling panels beneath the sprinklers, offering a visually uncluttered experience. Alongside this our horizontal containment comes with the option of state of the art manual and electronic data center doors.
Thermodynamically advantageous
Enhanced efficiency
Cost-effective
Low-maintenance
Quick and easy installation
Modular
Retrofittable
Re-locatable

Horizontal Aisle Containment

Door Options

Aisle Air Containment fully encases the corridor with a rigid enclosure which maximises the efficient use of cold air being fed in through the raised floor. The corridor remains light as light transmission (LUX) from the data center is let in through the lightweight transparent ceiling panels which have a transparency of an impressive 88%.

Vertical Aisle Containment

Door Options

Electronic door - Outstanding user convenience and unique operational behaviour characterize the automatic sliding door operator. The door is magnetically driven and therefore silent in operation. Additionally the drive method allows for unparalleled levels of safety for the user.
Manual door - The manual door option is a state of the art sliding door closer with a hold open facility and fully adjustable damper system as standard. This ultra smooth and superbly quiet sliding door closer provides the very best quality for your application.

Vertical Aisle Containment

Lighting

The aisle beacon is controlled by a BT10 universal interface module which takes an input from the 100v loudspeaker circuit on the building fire alarm. The BT10 and a 24v relay are mounted in a Beacon Box assembly (CC6-0100-AP). The beacon is installed in the central service panel of the aisle. The customer is responsible for arranging connection of the 110v line input from the fire alarm system.
Operation Temperature: -20˚/+50˚C
Dual voltage 12/24V (10-30Vdc)
Light Source: Chip LED
Bright, intense Xenon flash
Light Color: Natural White (3800-4200 K)
No moving parts – maintenance free
Beam Angle: 120˚ without lens
Low power consumption
Light Efficacy: 105 lm/W
3,000 hours tube life
Operation Voltage: 100-240V 50/60Hz.
Operating temperature -30°C to -55°C
Power Consumption (W): 10W/m
Beam Angle: 120˚ without lens

OUR PRODUCTS

You may also like

ColdLogik
Rear Door Heat Exchanger

CL21 Passive Rear Door Heat Exchanger

The CL21 Passive RDHx offers high-performance cooling at zero-operational cost.
EDGE
EDGE Solutions

EDGE-3 Soundproof MDC

Enables quiet computing in limited space with advanced intelligence and security features.
ColdLogik
Rear Door Heat Exchanger

CL20 Active Rear Door Heat Exchanger

Efficient cooling solution for data centers, optimizing performance and reliability.
USpace
Server Cabinet

USpace - 4210 Cabinet

Cost-effective and versatile Rack, adapts to diverse applications, offering ease and flexibility.
ColdLogik
InRow Coolers

CL80 600W InRow Cooler

Precision cooling solutions for aisle containment, ensuring optimal performance.
ColdLogik
InRow Coolers

CL80 300W InRow Cooler

The highest cooling capacity available in a footprint of a chilled water InRow.
USpace
Server Cabinet

USpace - 5210 Cabinet

High-density design with flexible configuration for evolving IT environments.

USystems

Data Center Solutions
that Exceed Expectations

Get in touch with us at USystems Ltd to join the journey towards more efficient and sustainable data centers. Our leading and innovative technologies are designed to help you use less energy and reduce your carbon footprint on a global scale. Contact us now to explore how we can work together for a greener future.
Slider with Navigation Buttons